The data in words
A vertical cross-section, altitudes to scale up to 80 km. A Thermal Chimney rises from 1 km to 65 km. Fans at its base pull 737 K air through heat exchangers at 20 m/s, cooling it by 300 K; the cooled air drains into a lowland basin. Sealed liquid loops, stage by stage, lift 1.2 × 10¹⁵ W per chimney to the Exhaust canopy, 80 km across, whose tiles fire 2.3 µm light into 25° cones, 3.0 × 10¹⁵ W per canopy. The clouds lie between 48 km and 70 km. The Braking Ring at 400 km takes the Lattice's beam at 10 MW/m², sheds its receiver loss heat at 1,500 K, and sends power down tethers to the canopies. In the basin, after 2036, dry ice 2 km thick at 180 K lies under a cap of 2 m of basalt, 20 m of aerogel and a 1 mm membrane; heat pipes 200 m into the floor carry 12 PW at first up a riser to radiators on the cap.
| Element | Where | What it does |
|---|---|---|
| Thermal Chimney | 1 km to 65 km | lifts 1.2 × 10¹⁵ W in sealed liquid loops |
| Intake fans and exchangers | from 1 km | cool 737 K air by 300 K |
| Exhaust canopy | 65 km | throws 3.0 × 10¹⁵ W to space at 2.3 µm |
| Clouds | 48 km to 70 km | sulfuric acid |
| Braking Ring | 400 km | takes the Lattice beam at 10 MW/m²; power down tethers |
| Basal heat pipes | 200 m into the basin floor | carry 12 PW at first |
Principle
Venus's heat is in its deep air. The atmosphere's scale height is , so most of its mass, and most of its heat, sits in the lowest few tens of kilometers, at up to and . The Photonic Exhaust can only shine its heat to space from high up, above most of the CO₂, at the canopies up. Something has to carry the heat between the two, at a rate the air will never manage by itself: near the ground Venus's air barely moves.
The obvious design, and version 2's, is a duct: let the hot deep air rise inside a column to the canopy, give up its heat there, and sink outside. It does not work, and the reason is the most important fact about Venus's atmosphere.
So version 3's chimneys lift heat, not air. The heat leaves the air where the air is, at depth, and climbs in a liquid. A liquid is nearly incompressible: the huge change in pressure over the tower's height changes its temperature only a little. The heat reaches the canopy close to the temperature of the air it came from, which is why the model can treat the Exhaust's cold side as the air's own temperature.
Design
Intakes. Each chimney's intake stages carry maglev fans that pull the surrounding air through heat
exchangers at , across the tower's full section,
. At the base, above the ground,
that is of gas at .
The exchangers cool it by . With CO₂'s heat capacity of
, Q = ṁ c_p ΔT gives per chimney.
Liquid loops. The heat passes into a cascade of sealed liquid loops that climb the tower, each a few kilometers tall, each handing its heat to the next through an exchanger. A loop's rising leg is hot and light, its falling leg cool and dense, so the loops largely drive themselves. Splitting the climb into stages keeps the pressure in any one loop manageable. The top loop delivers the heat to the exchangers under the canopy floor, where the Exhaust's tiles take it.
The cooled air. Air leaving an exchanger is far denser than the air around it. It flows out of the bottom of the intake and drains downhill into the lowland basins, where it pools: cold air under hot, the stable layering that keeps the two from mixing back. The intake sits above the ground so that it draws from the hot air above the pool; as the cold layer deepens, higher intake stages take over. The basins that fill with cold air are the same basins that later fill with liquid CO₂.
Structure. The air inside and outside the tower is at the same pressure, so the walls carry no pressure load. Each chimney hangs in tension from its floating canopy and is tethered to a ground anchor. On the way up it passes through the sulfuric-acid clouds between and .
Grid and capacity. There is one chimney under each of the canopies, on a grid about apart. Together they can lift , times the design peak of deep heat flow. The day-by-day simulation does not yet cap cooling at the chimneys' capacity. In its fastest weeks, in the first half of 2033, it removes heat slightly faster than the chimneys can lift it; after the Ring takes over the Railheads in , it stays above the design peak but within capacity.
Life cycle. The chimneys are built from the canopies down in 2032, under the closed Veil, and run hardest from through the Clear Rain of . After that their exchangers double as condensers: liquid CO₂ forms on them and drains to the basins. As the CO₂ rains out the air thins, the canopies float lower and the towers are shortened. They retire once the CO₂ is down, in , and their carbon goes into the cryo-continent caps.
Specifications
| Parameter | Value |
|---|---|
| Number | , one per canopy, about apart |
| Diameter | |
| Height | above the surface to |
| Gas at the base | , , |
| Flow speed | |
| Mass flow | each |
| Heat delivered | each, cooling the gas by |
| Total capacity | , times the peak deep heat flow |
What is invented
Version 3 changes how the chimney works, from rising gas to rising liquid; the model's numbers are unchanged, because they describe the air drawn through the intake and the heat taken from it.
Build sequence
- : The Veil closes. Canopies float at the cloud tops and the chimneys are lowered from them to their ground anchors.
- : Active cooling begins. The chimneys feed the Exhaust as fast as the growing Lattice can pay for pumping.
- : The Railheads on Ceres take most of the Lattice's power; cooling slows until the Ring pays for them.
- : The Clear Rain. The deep air falls below CO₂'s critical temperature and the exchangers start condensing liquid CO₂.
- : The Ring powers the Railheads and the Exhaust runs at its limit, with the chimneys lifting heat well above the design peak.
- : All the CO₂ is down. The chimneys retire and are taken apart.
- : Active cooling ends.
Failure modes and safeguards
- A collapse. A fallen chimney slows cooling only in its own cell. The rest have twice the design peak's capacity between them and take up the load.
- Acid. The towers pass through the sulfuric-acid clouds. Crawler robots inspect and patch the walls continuously, and the clouds rain out as the air cools (Acid Sweep).
- A leaking loop. Each loop is a sealed stage. A leaking stage is isolated and its neighbors carry the heat around it.
- A lost anchor. The tower hangs from its canopy, so losing the anchor lets it swing, not fall.
- Fans and exchangers. There are many intake stages on every tower; losing some lowers that chimney's share of the load, not the plan's.
- The physics. The design depends on keeping the heat in a liquid all the way up. If a stage lets its fluid boil or its pressure fall too far, that stage cools like the air does and delivers less useful heat. Loop design is part of the invention.
Reproduce these numbers
The chimneys' numbers come from calc/src/model/exhaust.ts, which models them with the Exhaust they feed.
pnpm calc --only chimney-heat # ṁ c_p ΔT for one chimney
pnpm calc --only chimney-mass-flow # ρ v A at the base
pnpm calc --only chimney-capacity # all chimneys together
Try pnpm calc --set chimney-gas-cooling=150 or a lower chimney-flow-speed: capacity falls in proportion, and the
margin over the design peak disappears. Raising chimney-count adds
capacity and narrows the grid.